SAFETY WARNINGS

LASER RADIATION

The OTOT-1000C laser transmitter emits invisible radiation that can cause permanent
eye damage.

. Operate the transmitter only

with the proper optical fiber installed in the transmitter optical connector. The OTOT-
1000C should be turned-off or disconnected whenever the optical connector cover is
opened and there is no installed fiber (as when the fiber connector is being installed or
removed from the transmitter connector).

AVOID DIRECT EXPOSURE TO BEAM

NEVER

NEVER
NEVER

NEVER

USE ANY OPTICAL INSTRUMENT TO VIEW THE OUTPUT OF THE

LASER TRANSMITTER. “OPTICAL INSTRUMENT” INCLUDES MAGNIFYING
GLASSES, ETC.

LOOK INTO THE OUTPUT OF THE LASER TRANSMITTER

LOOK INTO THE OUTPUT OF A FIBER CONNECTED TO A LASER

TRANSMITTER.

LOOK INTO OR USE ANY OPTICAL INSTRUMENT TO VIEW THE

DISTANT END OF A FIBER THAT MAY BE CONNECTED DIRECTLY OR VIA AN
OPTICAL SPLIT, TO A TRANSMITTER THAT MAY BE OPERATING. THIS
SPECIFICALLY APPLIES TO FIBERS THAT ARE TO BE CONNECTED TO
RECEIVERS (SUCH AS THE OTPN-400C or OTPN-2000C) OR OTHER
DEVICESATANY DISTANCE FROM THE LASER TRANSMITTER.

HIGH VOLTAGE

FIRE HAZARD

SHOCK HAZARD

- The inside of the OTOT-1000C contains no user serviceable parts.

There is exposed high voltage inside this unit. Only factory service technicians should
open the unit with power applied.

- The AC line input fuse is contained in the IEC 320 power input

connector. This fuse is a 250V, 0.5A, 5x20mm, slow blow fuse. To avoid a risk of fire, this
fuse should be replaced only with an identically rated fuse.

- The OTOT-1000C is designed for indoor use only. Direct exposure

to moisture must be avoided.