beautypg.com

Olson Technology OTM-3000 (PAL I) User Manual

Page 4

background image

025-000137 REV B

Page 4

C)

Adjust the aural carrier level control to the desired level, typically 15dB below the video carrier.
CAUTION: Reducing the visual/aural carrier ratio to less than 15dB can result in high out-of-band
spurious signals in adjacent channels.

7) MISCELLANEOUS

A)

This unit is equipped with video and audio I.F. loops. Both loops are connected with two type F short
jumpers. If these become disconnected or misplaced, then the OTM-3000-I will not perform prop-
erly.

B)

If a scrambling unit is utilized with the OTM-3000 I, follow the instructions associated with the scram-
bler. The video I.F. output level is +40dBmV, and the audio carrier level is determined by the aural
carrier level adjustment - typically +17dBmV @ 15dB A/V ratio.

C)

This unit is equipped with a 0.25 slo-blo fuse. For continued safety and to maintain proper perfor-
mance of the unit, please replace only with an equivalent fuse.

D)

A -20dB test point (type F connector) is provided on the rear panel.