STATUS DISPLAY PANEL OPERATION

The microprocessor software monitors the function of a number of system parameters. Pressing the andbuttons allows

the LCD to display key working parameters sequentially.

Optical Input Power

Input power: INPUT = display input power (dBm)

Input power = +10dBm = >alarm

Input power = -10dBm => display NO INPUT =>shut down the power supply of the laser.

Input power = 0dBm => reach fixed output power.

Optical Output Power

Output: OUTPUT = display output power (dBm)

Tolerance =

±0.2dBm

No input = power supply of the laser will be shut down automatically => display NO INPUT => NO OUTPUT

Laser Temperature

Laser temperature: TEMP = laser temp is set to operate in the range of 20-30°C

if exceeded => LCD will display

” READY” => red LED indicator will light, and the power supply of the laser will shut down auto-

matically.

Laser Bias

Bias: BIAS = Bias is the key index of the laser, if it exceeds the fixed range power supply of the laser, the power supply will

be shut down automatically to protect the laser.

Laser Heating/Cooling

Cooling/heating: COOLING/HEATING = standard temperature for laser 25°C

TEC

Thermoelectric cooler 25°C

At heat circumstance, LCD display => COOLING

At cool circumstance, LCD display =>HEATING

Voltage

+5V Voltage: +5V READS… => ±0.5V alarm

-5V Voltage: -5V READS… => ±0.5V alarm

Serial Number

Displays the serial number of the EDFA.

IP Address for RS-232 Connector