beautypg.com

Indicators and test points for lp-ot-10-rcxx – Olson Technology LP-OT-RCxx User Manual

Page 7

background image

Page 7 of 7

025-370503 REV X1

The optical power alarm LED is normally green. It turns red

on insufficient optical power. Optical ouput reads as shown below:

The laser current alarm LED is normally green. It turns red

on excessive laser current. At a typical laser current of 50mA the TP
will read 1.0V.

The cooler alarm LED is normally green. It turns red when

the cooler cannot keep the laser at a constant temperature.

The RF level adjust control allows for a 4dB range of input

level adjustment.

The RF test point is calibrated to read +10dBmV @ 25MHz

for proper laser modulation with 6 channel loading. This level will
change with channel loading. It does not require termination.

The optical output connector is type SC/APC, with optional

FC/APC connector available.

INDICATORS AND TEST POINTS FOR LP-OT-10-RCxx

The laser transmitter has front panel test points for optical power and laser current. Only a high impedance

voltmeter should be used. The meter common should be connected to the module ground test point, not to chassis
ground.

UNIT

OUTPUT TEST POINT VOLTAGE

LP-OT-10-RCxx

10.00mW

1.00V