LCM-500-550-DF ADDENDUM

The LCM-500-550-DF has a digital TV SAW filter in place of the normal VSB
SAW filter. To use as a I.F. to R.F. up converter, remove the I.F. jumper
between the “IF OUT” and “IF IN” connectors on the rear panel.

Connect the I.F. signal source to the “IF IN” connector. The level should
be +35 dBmV with a center frequency of 44.0 MHz.

Set the front panel DIP switches to the desired output frequency.

Description

I.F. Input

Center Frequency

44.0MHz

Level

+35dBmV

Impedance

75 Ohms

I.F. to R.F. Response

Gain

20dB Minimum

1 dB Bandwidth

5.0MHz Typical

3 dB Bandwidth

6.0MHz Typical

Group Delay

+/- 40 nS Typical

Additional Specifications