3110-100 Audio Control Panel Manual

Input Level, Rated

250 mVrms

Dynamic Range

20 mVrms - 1.5 Vrms (MIC input to COM output only)

DC Bias:

22

±5 mA at 15 Vdc

Keyline:

(RADIO PTT, CKPT INPH PTT, HAND MIC
PTT, SVC PTT)

Level: Open

(

≥100 kΩ) (Inactive)

GND (<30

Ω) (Active)

Source Current:

<20 mA

Discrete Input:

(AUX MUTE INHIBIT, AUX LEVEL, AUX MUTE
SWITCH, CABIN CALL SW, EMER MODE IN,
OXY SWITCH, ANNUNC TEST)

Level:

18.5 to 36 V (HI)
<3.5 V (LO)

Impedance:

≥100 kΩ, AUX MUTE INHIBIT ≥ 50 kΩ

Source Current:

<20 mA

Analog Receiver/Sidetone:

(RCVR, SDTN)

Type:

Differential, AC coupled, transformerless

Input Level:

See Table 1

Impedance: 2

k

Ω single ended (LO grounded), or

4 k

Ω differential

Analog Aural Warning:

(AUX)

Type:

Differential, AC coupled, transformerless

Input Level:

See Table 2

Impedance: 10

k

Ω single ended (LO grounded) or

20 k

Ω differential

Priority Detection Threshold: 90 ± 20 mVrms

EMER Receiver:

(VHF BKUP RX)

Type:

Single ended, transformerless, passive resistor
bypass

Input level:

7.75 Vrms nominal

EMER Aural Warning:

(AUX BKUP)

Type:

Single ended, transformerless, passive resistor
bypass

Input level:

See Table 2 in section 1.4.1.3

Aug 25, 2005