Northern Airborne Technology 247 User Manual
Page 15
247-xxx
Environmental Qualification Form
Rev: 1.00
Aug 4, 2009
Page 2 of 2
ENG-FORM: 521-0102.DOT
CONFIDENTIAL AND PROPRIETARY TO NORTHERN AIRBORNE TECHNOLOGY LTD.
Conditions
Section
Description of Conducted Tests
Fungus resistance
13.0
Category X, no test performed
Salt spray
14.0
Category X, no test performed
Magnetic effect
15.0
Class Z
Power input
16.0
Categories B and Z
Equipment met requirements for Emergency
Electrical System Operation per DO-160C
subparagraph 16.5.2.1 b (3)
Voltage spike
17.0
Category A
Audio frequency conducted
susceptibility
18.0
Category A
Induced signal susceptibility
19.0
Category A
Radio frequency susceptibility
20.0
Change No. 3
Category T
Emission of radio frequency
energy
21.0 Category
Z
Lightning induced transient
susceptibility
22.0
Change No. 2
Category XXC2
Lightning direct effect
23.0
Category X, no test performed
Icing
24.0
Category X, no test performed
REMARKS:
Model 247-xxx was qualified to the environmental test requirements of RTCA DO-160C by similarity to
Model 250-xxx
- Tests of DO-160C, Sections 4.0 (paragraphs 4.5.1, 4.5.2, and.4.5.3), 5.0, 16.0 and 18.0 were
conducted on the Model 250 at dB Systems, Inc. in Redmond, Washington.
- Tests of DO-160C, Sections 4.0 (paragraph 4.6.1), 6.0, 7.0, 8.0, 15.0, 17.0, 19.0, 20.4 (cond. susc.),
21.0, and 22.0 were conducted on the Model 250 at the Eldec Corporation in Lynnwood, Washington.
- Tests of DO-160C, Sections 4.0 (paragraphs 4.6.2, and 4.6.3) and 20.5 (radiated susc.) were
conducted on the Model 250 at Allied Signal in Redmond, Washington.
End of Environmental Qualification Form