Northern Airborne Technology 250 User Manual
Page 24
EQUIPMENT MANUAL 250-16-1
250/250-16-1
Page 15
Table 2. Environmental Qualification Form (continued)
TYPE/MODEL/PART NO.: Model 250-[ ]
CONDITIONS
DO-160C
SECTION/
PARAGRAPH
DESCRIPTION OF CONDUCTED TESTS
Sand and dust
12.0
Equipment identified as Category X, no test
required.
Fungus resistance
13.0
Equipment identified as Category X, no test
required.
Salt spray
14.0
Equipment identified as Category X, no test
required.
Magnetic effect
15.0
Equipment is Class Z.
Power input
16.0
Equipment tested to Categories B and Z.
Voltage spike
17.0
Equipment tested to Category A.
Audio frequency conducted
susceptibility
18.0
Equipment tested to Category A.
Induced signal susceptibility
19.0
Equipment tested to Category A.
Radio frequency susceptibility
20.0
Equipment tested to Category T.
Emission of radio frequency energy
21.0
Equipment tested to Category Z.
Lightning induced transient
susceptibility
22.0
Equipment tested to Category XXC2.
Lightning direct effects
23.0
Equipment identified as Category X, no test
required.
Icing
24.0
Equipment identified as Category X, no test
required.
Other Tests: Acceptance tests in accordance with dB Systems’ Acceptance Test Procedures 250-4
and performance tests in accordance with RTCA Document DO-214, Section 2.8 were conducted on
the Model 250 qualification test unit during and/or after each environmental test, as appropriate.
Remarks:
•
Tests of DO-160C, Sections 4.0 (paragraphs 4.5.1, 4.5.2, and 4.5.3), 5.0, 16.0, and 18.0 were
conducted at dB Systems, Inc. in Redmond, Washington.
•
Tests of DO-160C, Sections 4.0 (paragraphs 4.6.2 and 4.6.3) and 20.0 (radiated susc.), were
conducted at Sundstrand Data Control, Inc. in Redmond, Washington.
•
Tests of DO-160C, Sections 4.0 (paragraph 4.6.1), 7.0, 8.0, 15.0, 17.0,19.0, 20.0 (conducted
susc.), 21.0, and 22.0 were conducted at Eldec Corporation in Lynnwood, Washington.