beautypg.com

Northern Airborne Technology 250 User Manual

Page 24

background image

EQUIPMENT MANUAL 250-16-1

250/250-16-1

Page 15

Table 2. Environmental Qualification Form (continued)


TYPE/MODEL/PART NO.: Model 250-[ ]


CONDITIONS

DO-160C
SECTION/
PARAGRAPH


DESCRIPTION OF CONDUCTED TESTS

Sand and dust

12.0

Equipment identified as Category X, no test
required.

Fungus resistance

13.0

Equipment identified as Category X, no test
required.

Salt spray

14.0

Equipment identified as Category X, no test
required.

Magnetic effect

15.0

Equipment is Class Z.

Power input

16.0

Equipment tested to Categories B and Z.

Voltage spike

17.0

Equipment tested to Category A.

Audio frequency conducted
susceptibility

18.0

Equipment tested to Category A.

Induced signal susceptibility

19.0

Equipment tested to Category A.

Radio frequency susceptibility

20.0

Equipment tested to Category T.

Emission of radio frequency energy

21.0

Equipment tested to Category Z.

Lightning induced transient
susceptibility

22.0

Equipment tested to Category XXC2.

Lightning direct effects

23.0

Equipment identified as Category X, no test
required.

Icing

24.0

Equipment identified as Category X, no test
required.

Other Tests: Acceptance tests in accordance with dB Systems’ Acceptance Test Procedures 250-4
and performance tests in accordance with RTCA Document DO-214, Section 2.8 were conducted on
the Model 250 qualification test unit during and/or after each environmental test, as appropriate.
Remarks:

Tests of DO-160C, Sections 4.0 (paragraphs 4.5.1, 4.5.2, and 4.5.3), 5.0, 16.0, and 18.0 were
conducted at dB Systems, Inc. in Redmond, Washington.

Tests of DO-160C, Sections 4.0 (paragraphs 4.6.2 and 4.6.3) and 20.0 (radiated susc.), were
conducted at Sundstrand Data Control, Inc. in Redmond, Washington.

Tests of DO-160C, Sections 4.0 (paragraph 4.6.1), 7.0, 8.0, 15.0, 17.0,19.0, 20.0 (conducted
susc.), 21.0, and 22.0 were conducted at Eldec Corporation in Lynnwood, Washington.