Aa30-3xx – Northern Airborne Technology AA30-3xx User Manual
Page 22
AA30-3xx
Environmental Qualification Form
Rev: 1.00
Oct 20, 2006
Page 2 of 3
ENG-FORM: 521-0102.DOT
CONFIDENTIAL AND PROPRIETARY TO NORTHERN AIRBORNE TECHNOLOGY LTD.
Conditions
Section
Description of Conducted Tests
Vibration
8.0
Equipment tested to Category [(RBB1)(SM)]
(without shock mounts).
• The equipment was also tested to vibration
profile F (one hour per axis) per DO-160E
sub-paragraph 8.3.3 a) and met the minimum
performance standard.
Explosion
9.0
Equipment identified as Category X no test
required.
Waterproofness
10.0
Equipment identified as Category X no test
required.
Fluids Susceptibility
11.0
Equipment identified as Category X no test
required.
Sand and Dust
12.0
Equipment identified as Category X no test
required.
Fungus
13.0
Equipment identified as Category X no test
required.
Salt Spray
14.0
Equipment identified as Category X no test
required.
Magnetic Effect
15.0
Equipment is Class Z.
Power Input
16.0
Equipment tested to Category Z.
• Equipment was tested to subparagraph
16.6.1.3 b, requirement for digital circuits.
• Emergency Operating Voltage was tested.
Voltage Spike
17.0
Equipment tested to Category A
Audio Frequency Susceptibility
18.0
Equipment tested to Category Z
Induced Signal Susceptibility
19.0
Equipment tested to Category [AC]