beautypg.com

8 post-installation emi test, 4 continued airworthiness, 5 accessories required but not supplied – Northern Airborne Technology NTX403 User Manual

Page 17: 6 installation drawings, Ntx403, Ntx403-000

background image

SM64 Rev. 4.00

NTX403 Series Remote Mount UHF-FM Transceiver Manual


2.3.8

Post-Installation EMI Test

The purpose of this test is to identify any interference that the transceiver may cause
with existing aircraft systems. The transceiver should be tested in accordance with the
Installation Approval Test Procedure (see section 2.6) and the test results documented
on the record sheets.

Upon satisfactory completion of all performance checks, make the required log
entries and complete the necessary Regulatory Agency paperwork before
releasing the aircraft for service.

2.4

Continued Airworthiness

Maintenance of the NTX403 is ‘on condition’ only. Periodic maintenance of this product
is not required.

2.5

Accessories Required But Not Supplied

Installation kit p/n NTX-IKC (crimp) is required to complete the installation. The kit
consists of the following:

Quantity

Description

NAT Part #

1

Field Serviceable BNC Coax Connector

20-51-001

1

1/4 ATR NTX Mounting Tray

NTX-VT1

1

D-min 25 Pin Female Crimp Installation Kit

D25SV-IKC

Consisting of:

Quantity

Description

NAT Part #


1

D-min 25 Socket housing

20-21-025

25

MS Crimp Socket

20-26-901

1

25 pin JVL Hood/Locklever

20-29-250

2.6

Installation Drawings


DRAWING REV.

DESCRIPTION

TYPE

NTX403\403-0

1.00

NTX UHF Radio Connections

Interconnect

NTX403\405-0

1.00

UHF FM Transceiver

Connector Map

NTX403\634-0

1.00

UHF FM Transceiver

Installation Approval Test Procedure

NTX403-000\922-0

1.00

Remote Mount UHF FM Transceiver

Mechanical Installation


Section 2 ends after these Drawings