background image

AA34 Series Universal Radio Interface

SM36 Installation and Operation Manual

Section 2 Rev: 1.00

Issue 4

Page 2-6

2.5.3

Internal Adjustments (AA34-300 and AA34-301 only)

CAUTION:

The AA34 Series Universal Radio Interface contains static sensitive devices.

Proper ESD handling procedures must be followed to prevent damage to the unit.

Sidetone Level

Adjustment

Mic Output Level

Adjustment

Mic Output

Jumper

Audio

Output

Jumper

RX Level
Adjustment

C1/C2 Mic

Isolation/Direct

Switch

S1
S2

S1 Mic DC Bias
S2 Mic Output Blocking


2.5.3.1

8/600

Ω Audio Output Impedance Adjustment

Remove the cover from the AA34 and locate the 8/600

Ω adjustment jumper JP2. When the jumper is

connected across pins A and B, the unit is set to operate with an 8

Ω load connected. When connected

across B and C, the unit is set to operate with a 600

Ω load connected. (The default setting is B – C).

2.5.3.2

8/150

Ω Mic Output Impedance Adjustment

Remove the cover from the AA34 and locate the 8/150

Ω adjustment jumper JP1. When the jumper is

connected across pins A and B, the unit is set to operate with an 8

Ω load connected. When connected

across B and C, the unit is set to operate with a 150

Ω load connected (The default setting is B – C).




ENG-FORM: 805-0121.DOT