beautypg.com

Installation, 1 introduction, 2 unpacking and inspection – Northern Airborne Technology VR28 User Manual

Page 11: 3 installation procedures, 1 warnings, 2 cautions, 3 cabling and wiring

background image

SM32 Rev. 4.00

VR28-013 Voltage Regulator Manual

Section 2.0 Installation

2.1

Introduction

Information in this section consists of: unpacking and inspection procedures, installation
procedures, post-installation checks, and installation drawings.

2.2

Unpacking and Inspection

Unpack the equipment carefully and locate the warranty card. Inspect the unit visually
for damage due to shipping and report all such claims immediately to the carrier
involved. Note that each unit should have the following:


- VR28-013 Voltage Regulator
- Warranty Card
- Release certification

Verify that all items are present before proceeding and report any shortage immediately
to your supplier.

Complete the warranty card information and send it to NAT when the installation is
complete. If you fail to complete the warranty card, the warranty will be activated on
date of shipment from NAT.

2.3 Installation

Procedures

2.3.1 Warnings

Do not bundle any lines from this unit with transmitter coax lines. Do not bundle any
logic or audio lines with this unit. Do not position this unit next to any device with audio
interfaces, or significant audio interference will result.

2.3.2 Cautions

In all installations, use shielded cable exactly as shown, and ground as indicated.
Significant problems may result from not following these guidelines.

2.3.3

Cabling and Wiring

All wiring should be at least 22 AWG, except power and ground lines, which should be
at least 18 AWG. Ensure that all ground connections are clean and well secured.