Section 2 Installation

2.1

Introduction

Information in this section consists of unpacking and inspection procedures, installation procedures, post-
installation checks and installation drawings for the RA Series Remote Attenuator.

Review all notes, warnings and cautions.

2.2

Unpacking and Inspection

Unpack the equipment carefully and locate the warranty card. Inspect the unit visually for damage due to
shipping and report all such claims immediately to the carrier involved. Check that all items listed below
are present before proceeding and report any shortage immediately to your supplier:

- Warranty Card

- Certificate of Conformity or Release Certification

2.2.1

Warranty

All Northern Airborne Technology Ltd. products are warranted for 2 years from date of installation by an
authorized NAT dealer, to be free of defects in workmanship or performance. This warranty covers all
materials and labour, but is exclusive of any transport to deliver the defective unit to and from NAT or its
designated warranty repair center, or any labour to remove or re-install the defective unit in the aircraft.
Contact NAT for any questions regarding this warranty, its applicability to your units and/or for return
authorization. NAT is the final arbitrator concerning warranty administration. Units which have been
physically damaged, burned, immersed in water or otherwise abused beyond the scope of normal use will
not be considered for warranty. WARRANTY IS VOID UNLESS THE PRODUCT IS INSTALLED BY AN
AUTHORIZED NAT DEALER
. Product for which a warranty card is not returned shall be warranted from
date of manufacture.

2.3

Continued Airworthiness

Maintenance of the RA Series Remote Attenuator is ‘on condition’ only. Periodic maintenance of this
product is not required.

2.4

Installation Procedures

2.4.1

Cabling and Wiring

All wire shall be selected in accordance with the original aircraft manufacturer's Maintenance Instructions
or AC43.13-1B Change 1, Paragraphs 11-76 through 11-78. Unshielded wire types shall qualify to
MIL-W-22759 as specified in AC43.13-1B Change 1, Paragraphs 11-85, 11-86, and listed in Table 11-11.
For shielded wire applications, use Tefzel MIL-C-27500 shielded wire with solder sleeves (for shield
terminations) to make the most compact and easily terminated interconnect. Follow the connector map in

Section 2.7 as required.