3 environmental specifications, 5 unit nomenclature – Northern Airborne Technology RS16 User Manual
Page 8

RS16 Series Remote Switch Manual
SM15 Rev. 4.00
Page 1-2
Nov 24, 2003
ENG-FORM: 800-0106.DOT
CONFIDENTIAL AND PROPRIETARY TO NORTHERN AIRBORNE TECHNOLOGY LTD.
1.4.3 Environmental
Specifications
Operating Temperature
-40
°C to +70°C
Altitude
35,000 ft. max.
Humidity
95 % Non-Condensing
Shock
12 g. (any axis)
1.5 Unit
Nomenclature
NOTE: The RS128 and RS192 families are derivative products that simply contain
multiple RS16 cards in a single enclosure. All performance characteristics and test
procedures are the same as those for the RS16.
Model
Description / Distinction
RS16-001
16P2T data switch, GREEN annunciation. Can be mapped for voltage or
ground keying. ILS reversion relay.
RS16-101 16P2T data switch, card only (does NOT include enclosure), GREEN
annunciation. Can be mapped for voltage or ground keying. ILS reversion relay.
RS16-102
16P2T data switch, card only (does NOT include enclosure), RED annunciation.
Can be mapped for voltage or ground keying. ILS reversion relay.
RS128-000 Empty enclosure, allocated space for 8 RS16 cards. User may choose
combinations of RS16 cards.
RS128-008 Pre-filled with 8 RS16-101 cards for 128P2T operation.
Each RS16 card has an ILS reversion relay.
RS128-999 Pre-filled with 8 RS16-101 cards. Each RS16 card is hard-wire jumpered
to the normally closed position for each of the 16 contacts (relays
removed). Used to permit flight with the RS128-008 removed.
RS192-000 Empty enclosure, allocated space for 12 RS16 cards. User may choose
combinations of RS16 cards.
RS192-012 Pre-filled with 12 RS16-101 cards for 192P2T operation.
Each RS16 card has an ILS reversion relay.
RS192-999 Pre-filled with 12 RS16-101 cards. Each RS16 card is hard-wire jumpered
to the normally closed position for each of the 16 contacts (relays
removed). Used to permit flight with the RS192-008 removed.
End of section 1.0