RB25DET using RB20DET ECU
Air Conditioning output (23710-11UXX R32 ECU)
1. Remove RB25 Air conditioning output
A31: HCR32_FOR_RB25_11U00_74L00_MT_FP_TPS_VCT_ACOUT_v5.ent
R32: HCR32_FOR_RB25_11U00_MT_FP_TPS_VCT_ACOUT_v5.ent
Pin 113 - ECR33 RB25 - VCT output solenoid
Pin 9 - Air conditioner relay
2. Cut pin 9 from ECU
3. Solder pin 9 to pin 113