Multicon SNMP Data Model
Rev. 0
nevion.com | 9
3 Notifications
Multicon has the capability to send SNMP notifications (traps) when alarms occur in a
Flashlink system or VikinX router. The trap types supported are listed in the MIB file.
There are one trap type indicating the raise of an alarm and a corresponding trap type to
indicate clear of an alarm. Each trap type contains values from the SNMP data model
pertaining to the alarm situation, which enables SNMP managers to poll for more
information when a trap is received.
Example:
nworkLossOfOptSignal TRAP-TYPE
ENTERPRISE generic
VARIABLES { busSysType, busNum, moduleNum, moduleLabel, optInputNum }
DESCRIPTION "Loss of input signal on optical input."
::= 3
nworkCorrectOptSignal TRAP-TYPE
ENTERPRISE generic
VARIABLES { busSysType, busNum, moduleNum, moduleLabel, optInputNum }
DESCRIPTION "Signal on optical input comes back after having been lost."
::= 4
The example above shows an loss of optical signal alarm and a corresponding clear alarm. In
each case the values of busSysType, busNum, moduleNum, moduleLabel and optInputNum
is sent with the trap.