Nevion DA-3GHD-8-PL User Manual
Page 6

DA-3GHD-8-PL / DA-3GHD-8
Rev. D
nevion.com | 6
Cable equalization, DA-3GHD-8.
Format
Min.
Typical
Comments
SD-SDI
300m
Belden 8281
BER< 10E-12
Total length of cable included
patching between modules
325m
HD-SDI
150m
Belden 1694A
BER< 10E-12
Total length of cable included
patching between modules
200m
3GHD-SDI
70m
100m
Cable equalization, DA-3GHD-8-PL, single unit.
Format
Min.
Typical
Comments
SD-SDI
200m
1
,
2
Belden 8281
BER< 10E-12
Total length of cable included
patching between modules
225m
HD-SDI
50m
Belden 1694A
BER< 10E-12
Total length of cable included
patching between modules
75m
3GHD-SDI
30m
40m
Cable equalization, DA-3GHD-8-PL, two looped units.
Format
Min.
Typical
Comments
SD-SDI
Belden 8281
BER< 10E-12
Total length of cable included
patching between modules
HD-SDI
50m
Belden 1694A
BER< 10E-12
Total length of cable included
patching between modules
60m
3GHD-SDI
25m
25m
Cable equalization, DA-3GHD-8-PL, three looped units.
Format
Min.
Typical
Comments
SD-SDI
Belden 8281
BER< 10E-12
Total length of cable included
patching between modules
HD-SDI
30m
Belden 1694A
BER< 10E-12
Total length of cable included
patching between modules
50m
3GHD-SDI
20m
1
Measured with the following parameters at the limits of the standards simultaneously;
Amplitude (+/- 10%), Ambient temperature (0ºC/45ºC), Generator jitter:
-
SD-SDI:
10Hz-10kHz: >1 UI
10kHz
– 10MHz: >0.2 UI
-
HD-SDI:
10Hz-100kHz: >1 UI
100kHz
–150MHz: >0.2 UI
-
3GHD-SDI:
10Hz-100kHz: >2 UI
100kHz
–300MHz: >0.3 UI
2
Specified termination at the loop end required. 75 ohm terminations mounted at all unused output ports for HD-SDI
and 3GHD-SDI required.
3
Well within limits of standards