beautypg.com

Nevion DA-3GHD-8-PL User Manual

Page 6

background image

DA-3GHD-8-PL / DA-3GHD-8

Rev. D


nevion.com | 6

Cable equalization, DA-3GHD-8.

Format

Min.

Typical

Comments

SD-SDI

300m

Belden 8281
BER< 10E-12
Total length of cable included
patching between modules

325m

HD-SDI

150m

Belden 1694A
BER< 10E-12
Total length of cable included
patching between modules

200m

3GHD-SDI

70m

100m

Cable equalization, DA-3GHD-8-PL, single unit.

Format

Min.

Typical

Comments

SD-SDI

200m

1

,

2

Belden 8281
BER< 10E-12
Total length of cable included
patching between modules

225m

2,3

HD-SDI

50m

1,2

Belden 1694A
BER< 10E-12
Total length of cable included
patching between modules

75m

2,3

3GHD-SDI

30m

1,2

40m

2,3

Cable equalization, DA-3GHD-8-PL, two looped units.

Format

Min.

Typical

Comments

SD-SDI

200m

1,2

Belden 8281
BER< 10E-12
Total length of cable included
patching between modules

225m

2,3

HD-SDI

50m

1,2

Belden 1694A
BER< 10E-12
Total length of cable included
patching between modules

60m

2,3

3GHD-SDI

25m

1,2

25m

2,3

Cable equalization, DA-3GHD-8-PL, three looped units.

Format

Min.

Typical

Comments

SD-SDI

175m

1,2

Belden 8281
BER< 10E-12
Total length of cable included
patching between modules

200m

2,3

HD-SDI

30m

1,2

Belden 1694A
BER< 10E-12
Total length of cable included
patching between modules

50m

2,3

3GHD-SDI

15m

1,2

20m

2,3

1

Measured with the following parameters at the limits of the standards simultaneously;

Amplitude (+/- 10%), Ambient temperature (0ºC/45ºC), Generator jitter:
-

SD-SDI:

10Hz-10kHz: >1 UI

10kHz

– 10MHz: >0.2 UI

-

HD-SDI:

10Hz-100kHz: >1 UI

100kHz

–150MHz: >0.2 UI

-

3GHD-SDI:

10Hz-100kHz: >2 UI

100kHz

–300MHz: >0.3 UI

2

Specified termination at the loop end required. 75 ohm terminations mounted at all unused output ports for HD-SDI

and 3GHD-SDI required.

3

Well within limits of standards