Periodic inspection/maintenance – MMD Equipment 185S-5C2 part 2 User Manual
Page 13

5. Periodic Inspection/Maintenance
5-13
5.5.15 Change Oil Separator
[Every 2,000 hours]
When changing the oil separator, both cover and element must be replaced with new ones.
Even before the periodic interval time of replacement,
replace the oil separator whenever the oil consumption
increases and also oil is found mixed in the discharge air.
When consumption of the oil is still unusual even after
cleaning strainer in the scavenging orifice (See 5.5.7),
change the oil separator with a new one. (See 5.4)
Replacement of the oil separator requires expert technical
knowledge. So contact directly us or distributor.
5.5.16 Change Nylon Tubes
[Every 2,000 hours]
Replace nylon tubes used for the oil and air pipings.
Replacement of the nylon tube requires expert technical knowledge. So contact directly us or dis-
tributor.
5.5.17 Clean inside of Fuel Tank
[Every 2,000 hours]
Cleaning the inside of fuel tank. requires expert technical knowledge. So contact directly us or dis-
tributor.
A100113
Separator casing
Element
Cover
Separator cover
Oil
Separator
O-ring