beautypg.com

Problem cause correction – Delta A00543 User Manual

Page 15

background image

15- ENG

A00543

Water leaking
at pump

Water leaking at
gun/spray wand
connection

No or low
pressure
(after period of
normal use)

PROBLEM

CAUSE

CORRECTION

Spray wand not in low pressure.

See How to Use Spray Wand
paragraph in the Operation
Section.

Chemical screen not in cleaning
solution.

Clean filter.

Chemical too thick.

Dilute chemical. Chemical should
be the same consistency as water.

Pressure hose is too long

Lengthen water supply hose
instead of high pressure hose.

Chemical build up in chemical
injector.

Have parts cleaned or replaced
by AWSC.

Worn seal or packing

Have replaced by AWSC.

Worn or obstructed valves.

Have replaced by AWSC.

Worn unloader piston.

Have replaced by AWSC.

Worn E-Z start valve.

Check and replace.

Loose hose connection.

Loose connections.

Tighten.

Piston packings worn.

Have replaced by AWSC.

Worn or broken o-rings.

Have replaced by AWSC.

Pump head or tubes damaged
from freezing.

Have replaced by AWSC.

Will not draw
chemicals

Make sure end of chemical hose
is fully submerged into cleaning
solution.

Chemical filter clogged.

Worn or broken o-ring.

Tighten.

Have replaced by AWSC.

Oil leaking at
pump

Oil seals worn.

Have replaced by AWSC

Loose drain plug.

Worn drain plug o-ring

Worn fill plug o-ring.

Pump overfilled.

Incorrect oil used.

Vent plug is clogged.

Tighten.

Check and replace.

Check and replace.

Check for correct amount.

Drain and fill with correct amount
and type of oil.

Clean vent plug; blow air through it
to remove any blockage. If prob-
lem persists, replace plug.

Nozzle obstructed.

See Nozzle Cleaning paragraph in
the Maintenance section for the
correct procedure.

Pump Pulsates

This manual is related to the following products: