Care and maintenance, Safety procedures – MBM Corporation iCREASE PRO User Manual
Page 4

SAFETY PROCEDURES
BEFORE USE:
• Read through the owner’s manual. Follow instructions CAREFULLY.
• NEVER use a wet area. Electric shock could occur.
• Use a GROUNDED outlet and a GROUNDED circuit. Do not use ungrounded
equipment on the same circuit.
• Always use a dedicated line. DO NOT use with line splitting surge protector.
DURING USE:
• Keep fingers and hands away from creasing bar and rubber rollers.
• Keep cords clear of moving parts.
AFTER USE:
• Turn off machine at the cover, then unplug the main power cord. This will prevent
damage to your machine by power/voltage spikes.
• To unplug cords, always grasp the plug body, never pull on cords to disconnect. Wire
fatigue and possible shock could result from improper disconnect procedures.
BE ALERT! BE CAREFUL!
CARE AND MAINTENANCE
The
icreasePRO
is a precision machine. It is very important to keep it free of excessive dust, dirt
and foreign matter. We recommend that you keep the machine covered when not in use.
BEARINGS: The
icreasePRO
uses sealed roller bearings. Sealed roller bearings and are
designed to be self lubricating, however dirt and dust can get into them causing clogging and dirt
build up It is recommended to occasionally oil the sealed roller bearings under heavy use.
STRIKE DIE: The groove in the lower die should be cleaned periodically using a toothbrush to
remove any dirt or build up.
SENSOR EYE: Clean the lower reflector tape located on the base plate of the machine. Dust will
cause the beam to not reflect correctly. Clean when necessary.
REMOVEABLE SCREWS: When these show signs of wear or stripping, replace as soon as
possible. If these strip or hollow out they can be costly to remove. If you do keep
icreasePRO
clean and in top condition, it will give you years of service.
1b