Operator instructions
1. Make sure the main power is switched off on both machines.
For 300/400 series collator: Plug the Connection cable
between the jack on the stacker side of the Collator to the 25-
pin jack on the Model 82.
For Model 100 collator: Plug the 9-pin Connection cable
between the collator and the upper 9-pin jack of the
Communication box. Plug the other connection cable between
the 15-pin jack of the Communication box to the 25-pin jack
on the Model 82. Connect a termination plug in the lower 9-pin
jack of the Communication box. Connect another termination
plug in the Collator.
2. Connect the Power cord to the receptacle on the Model 82
and into the wall outlet. Switch on the Model 82 and Collator.
3. Move the Model 82 infeed end to the outfeed end of the
Collator. The docking assembly will automatically lock onto
the Collator when studs of the Collator enters the Model 82
A4 (8.5”) or A3 (11”)-position openings. The green mark on
the rear side guide corresponding to green strip on the
Collator helps you docking in the correct position.
4. The docking assembly is released by pressing the green area
on the side of the assembly.
5. If running an odd paper size, loosen the knob on the lower
side of the docking assembly. Move the Model 82 sideways
so the green mark on the rear side guide aligns with the green
strip on the Collator.
Normal position of the docking assembly is indicated by a
centring notch.
4.1 Connecting the Model 82 to a Collator
A3 / 11”
A4 / 8.5”
Adjustment
knob for
odd sizes
Studs
4-1
Communication
box
15-pin
jack
9-pin
connection
cable
Termination
plug
25-pin