Requirements, Electrical requirements, Grounding instructions – Maytag MDB6000AWW Installation User Manual
Page 2: Plumbing requirements, Door spring adjustment, Warning
The door has two main springs, one located on each hinge. There is a slot on the right hinge that will
allow for door adjustment with the access panel removed.
To change door spring tension, use a 1/4” hex-nut driver to either loosen or tighten the screw located
on the right door spring adjustment bracket.
CAUTION: Disconnect electrical power before you start!
All electrical wiring and grounding should be done
in accordance with national and local codes
The dishwasher is designed for
operation on an individual 120
VAC, 60 Hz grounded electrical
circuit.
Use required fuse (15 amp) or
comparable circuit breaker. Two
wire with ground service to the
dishwasher is recommended for
connections at the terminal box
and for grounding.
Electrical Requirements
St a r t H e r e
Requirements
Grounding Instructions
!
WARNING
CAUTION: To prevent accidental contact with electrical connections, built-in
dishwasher models must not be connected to a power source unless the
dishwasher is completely enclosed, with front panel in place. If the back or either
side of the dishwasher is exposed, a panel must be used to complete this
enclosure. Failure to follow this warning could result in death or serious injury.
!
WARNING
CAUTION: To prevent the possibility of electrical shock, this dishwasher, as other
electrical appliances, must be adequately grounded. It is the responsibility of
the installer at the point of installation, taking into consideration local conditions
and requirements. Failure to follow this warning could result in death or
serious injury.
Plumbing Requirements
!
WARNING
CAUTION: Disconnect electrical power to dishwasher
before you start! Failure to follow this warning could
result in death or serious injury.
Door Spring Adjustment
To increase spring tension: (If door falls too fast)
Tighten screw by turning clockwise.
To decrease spring tension: (If door falls too slowly)
Loosen screw by turning counterclockwise.
For heavy wood panels, an auxiliary booster spring kit
is available
Door Spring Adjustment Screw
2
This appliance must be connected
to a grounded metal, permanent
wiring system: or an equipment-
grounding conductor must be run
with the circuit conductors and
connected to the equipment-
grounding terminal or lead on the
appliance.
Check local plumbing code for
approved plumbing procedures
and accessories. All plumbing
should be done in accoradance
with national and local codes