Technical features, 6 technical features – Datalogic Scanning STARGATE User Manual
Page 37

TECHNICAL FEATURES
6
6 TECHNICAL FEATURES
Electrical Features
Micro-controller 16bit
CMOS
Program memory
128 Kb
Data memory
128 Kb
Supply voltage
9..30 Vdc
Power consumption
600 mW
Radio Features
European Models
USA Models
Working frequency
433.92 Mhz
910 Mhz
Bit rate
19200 baud
36800 baud
Effective radiated power
<10 mW
<1 mW
Range (in open air)
50 m / 164 ft
30 m / 98.4 ft
RF Modulation
FSK
Environmental Features
Working temperature
-20° to +50 °C / -4° to 122 °F
Storage temperature
-20° to +70 °C / -4° to 158 °F
Humidity
90% non condensing
Protection class
IP30
Mechanical Features
Weight (without fixing plate)
210 g / 7.4 oz
Dimension (without antenna)
141 x 111 x 52 mm / 5.6 x 4.4 x 2.0 in
LED
Power on/Data (green)
Communication/Downloading error (red)
Firmware downloading (yellow)
29