1.
Follow steps 1 through 5 under Lighting Instructions, page 18.
2.
Depress control knob and light pilot with match.
3.
Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob. Now follow
steps 8 and 9 under Lighting Instructions, page 18.
THERMOSTAT CONTROL
OPERATION
The thermostat control knob can be set to any comfort level
between HI and LO. The thermostat will gradually modulate the
heat output and flame height from higher to lower settings, or
pilot, in order to maintain the comfort level you select. The ideal
comfort setting will vary by household depending upon the amount
of space to be heated, the output of the central heating system, etc.
Note:
Selecting the HI setting with the control knob will cause the
burner to remain fully on, without modulating down in most cases.
MANUAL LIGHTING PROCEDURE
WARNING: If you do not follow these instructions
exactly, a fire or explosion may result causing prop-
erty damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone
in your building.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire de-
partment.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by
hand, don’t try to repair it, call a qualified service techni-
cian or gas supplier. Force or attempted repair may result
in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
FOR YOUR SAFETY
READ BEFORE LIGHTING
1.
STOP! Read the safety information in column 1.
2.
Make sure equipment shutoff valve is fully open.
3.
Set switch in OFF position.
WARNING:
• If fireplace has glass doors, never operate this
heater with glass doors closed. If you operate
heater with doors closed, heat buildup inside fire-
place will cause glass to burst. Also if fireplace
opening has vents at the bottom, you must open
the vents before operating heater.
• You must operate this heater with a fireplace screen
in place. Make sure fireplace screen is closed
before running heater.
NOTICE: During initial operation of new heater, burn-
ing logs will give off a paper-burning smell. Open
damper or window to vent smell. This will only last a
few hours.
Note:
Home owners generally prefer to operate their heater
with the chimney damper closed. This will put all the heat into
the room. However, there may be times you will desire the full
flames of the HI heat setting but will find the heat output
excessive. You can open the chimney damper (if you have one)
fully or partially to release some of the heat.
WARNING: Damper handle will be hot if heater
has been running.
4.
Press in and turn control knobs clockwise
to the
OFF position.
5.
Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Fol-
low “B” in the safety information, column 1. If you don’t
smell gas, go to the next step.
6.
Press in and turn control knob counterclockwise
to the PILOT position. Press in control knob for five (5)
seconds (see Figure 32, page 20).
Note:
You may be running this heater for the first time
after hooking up to gas supply. If so, the control knob may
need to be pressed in for 30 seconds or more. This will al-
low air to bleed from the gas system.
WARNING: Burner will come on automatically
within one minute when the remote selector switch is
in the ON position after the pilot is lit.
LIGHTING INSTRUCTIONS
OPERATING HEATER (THERMOSTAT-CONTROLLED MODELS)
Thermostat Control
Manual Lighting Procedure
OPERATING HEATER (REMOTE-READY MODELS)
For Your Safety Read Before Lighting
Lighting Instructions
REMOTE-READY MODELS