Lacava llc 5 – Lacava 260 User Manual
Page 5

Installation Instructions/Instrucciones de Instalación
1 3/16” - 2 1/2“
1. Determine the location of the valve. Make sure the center of the valve
will measure 1 3/16” - 2 1/2“ from the surface of the finished wall.
2. Position valve in the wall at the correct depth and secure
into place.
3. Install NPT threaded copper adapters to the hot & cold
inlets, applying teflon tape to all threaded connections.
Then solder copper piping onto adapters and run to
designated water supply or outlet.
Important! Take the following precautions if soldering copper
piping directly onto valve:
a) Remove ALL components from the valve prior to soldering,
including plaster guards & cartridges.
b) Wrap valve body with cold rag before soldering. Take
special care not to overheat brass rough-in.
c) Use copper piping only, do not attempt to solder steel
piping to valve.
d) Flush all pipes before reinstalling any cartridge and service stops.
e) Reinstall all components after soldering.
4. Make sure the cartridge is in the off position and then turn on
the water supply. Check for any connection leakage and make
any necessary repairs.
5. Finish the surrounding wall.
ESCUTCHEON
RING
ESCUTCHEON
CYLINDER
6. Unthread the escutcheon cylinder from the valve.
7. Insert escutcheon cylinder through escutcheon ring and thread back onto valve.
8. With insert inside the handle push handle onto the cartridge stem. Press straight on until you feel it snap into
place.
9. You may back the escutcheon cylinder out to fill any gap between the handle and the escutcheon.
10. Secure escutcheon ring to the wall with silicone.
LACAVA LLC
5
260.75