Instruction on mounting and use – Kleenmaid SAMURAI User Manual
Page 6
Consult the designs in the front pages referenced in the text
by alphabet letters. Closely follow the instructions set
out in this manual. All responsibility, for any eventual
inconveniences, damages or fires caused by not complying
with the instructions in this manual, is declined.
The rangehood must be placed at a minimum distance of 650mm
from the cooking plane for electric, gas and mixed cooktops.
Please confirm this measurement with your Local Building Authority.
The rangehood is equipped with a top air outlet "B“ for
discharge of fumes to the outside (Ducting version –
exhaust pipe and pipe fixing clamps not provided).
Should it not be possible to discharge cooking fumes and
vapour to the outside, the rangehood can be used in the filter
version, fitting an activated carbon filter and the deflector "F“
on the support (bracket) "G“, fumes and vapours are
recycled through the top grille "H“ by means of an exhaust
pipe connected to the top air outlet "B“ and the connection
ring mounted on the deflector "F“ (exhaust pipe and pipe
fixing clamps not provided).
The models with no suction motor only operate in ducting
mode, and must be connected to an external suction device
(not supplied).
Installation - Fig. 5
Preliminary information for installation of the rangehood:
Disconnect the rangehood during electrical connection, by
turning the home mains switch off.
Expansion wall plugs are provided to secure the rangehood to
most types of walls/ceilings. However, a qualified technician
must verify suitability of the materials in accordance with the
type of wall/ceiling. The wall/ceiling must be strong enough
to take the weight of the rangehood.
Do not tile, grout or silicone this appliance to the wall.
Surface mounting only.
Remove the grease filter/s.
1 . Using a pencil, draw a line on the wall, extending up to
the ceiling, to mark the centre. This will facilitate
installation.
2 . Rest the drilling template against the wall: the vertical
centre line printed on the drilling template must correspond
to the centre line drawn on the wall, and the bottom edge
of the drilling template must correspond to the bottom
edge of the rangehood: bear in mind that, when installation
is complete, the underside of the rangehood must be at least
650mm above the cooktop in the case of electric, gas and mixed
cooktops. Please confirm this measurement with your
Local Building Authority.
3 . Rest the support bracket on the drilling template so that
it coincides with the dotted rectangle, mark the two outer
holes and drill them, remove the drilling template, insert
2 wall plugs and fix the rangehood support bracket into place
using two 5x45mm screws.
4 . Hang the rangehood on the bracket.
5 . Adjust the distance of the rangehood from the wall.
6 . Adjust the horizontal position of the rangehood.
7. Remove the carbon filter frame (see also Fig. 3); mark
the drill hole, using a pencil, for fastening the rangehood
to the wall.
8 . Remove the rangehood from the bracket.
9 . Drill at the point marked (Ø8mm - see operation 7).
1 0 . Insert 1 wall plug.
1 1 . Rest the chimney support bracket "G“ against the wall,
touching the ceiling. Use the support bracket as a drilling
template (the small slot formed on the support must
coincide with the line drawn on the wall as above –
operation 1) and mark 2 holes with a pencil, drill the holes
(Ø8mm), insert 2 wall plugs.
1 2 . Fix the chimney support bracket to the wall using two
5x45mm screws.
1 3 . Hook the rangehood onto the bottom bracket.
14.Fasten the rangehood to the wall with one x 5x45mm
screw (ABSOLUTELY NECESSARY), remount the
carbon filter frame (see also Fig. 3).
1 5 . Connect a pipe (pipe and pipe clamps not provided, to
be purchased separately) for discharge of fumes to the
connection ring located over the suction motor unit.
If the rangehood is to be used in ducting version, the other
end of the pipe must be connected to a device expelling
the fumes to the outside. If the rangehood is to be used
in filter version, fix deflector "F“ to the chimney
support bracket "G“ using 4 screws, and connect the other
end of the pipe to the connection ring on deflector "F“.
1 6 . Make the electrical connections.
1 7 . Apply the chimney stacks and fasten them at the top to
the chimney support "G“ (17b) using 2 screws (17a).
1 8 . Slide the bottom section of the chimney down until it
completely covers the suction unit and slots into the
housing provided on top of the rangehood.
1 9 . Fasten the bottom section of the chimney with 2 screws
(only for model "A" - Fig. 1).
Replace the grease filter/s and check that the rangehood
is operating correctly.
Electrical connection
The electrical tension must correspond to the tension noted
on the label placed inside the rangehood. Connect the
electrical plug, where provided, to the an easily accessible
outlet in conformity with local standards in force.
Where an electrical plug is not provided (for direct connection
to electrical network) place a standards approved bipolar
switch with an aperture distance of not less than 3mm
(accessible) from the contacts.
INSTRUCTION ON MOUNTING AND USE