Instructions to the installer

The appliance must be installed by a qualified technician accordance with the instructions of this
booklet and in accordance with the current Australian Standards.

The oven must be installed in a housing which has been built to withstand a temperature of 120 °C
in accordance with EEC REGS.

The manufacturer declines any responsibility for faults arising from incorrect installation
and/or connection and/or inadequate ventilation.

Servicing information

Before calling for service be sure you know how to operate your oven: it may help you in explaining
the malfunction to the serviceman. Check that there is not a power cut (with the fuse still working).
When you call for service or order parts do not forget to give:

model of your oven

serial number

colour (when in enamelled version)

part name or/and description of the problem

your full name, address, home phone number, (or/and business phone number if appropriate).

Electrical connection

The oven fitted with 3x1.5 mm²

a cord set in which case connect the 15 A plug to a compatible

power outlet socket located in an adjacent cupboard and wall unit.

Important

The housing should not be free standing, but secured to the wall and/or adjacent fittings and housing,
do not lift it by the door handle. Do not force the oven into the housing using the open door as a
lever and never exercise excessive pressure on the open door. The oven should be secured to the
housing by nº 4 fitting screws in holes of the frame as shown in fig. 10.

Warning:

This appliance MUST be earthed.

This appliance must not be connected integrally with any appliance on the same sub-circuit.

Be sure that:

– earth wire is not interrupted by the switch.

– easy access to the switch is ensured once the appliance is installed

– the supply cable not comes in contact with any component the temperature of which exceed the

ambient temperature by 50°C and with sufficient length for allowing any subsequent removal of
the unit.

once connected the appliance is working correctly.

It is recommended that the power outlet be a dedicated circuit for use with the oven only.
Locating the power outlet directly behind the oven is not recommended.

IMPORTANT

The wires in the mains lead are coloured in accordance with the following code:
GREEN & YELLOW...............................................................EARTH
BLUE.................................................................................NEUTRAL
BROWN ....................................................................................LIVE