beautypg.com

Connection connection, Natural gas grills – Ducane Natural 3400 User Manual

Page 18

background image

18

www.ducane.com

CONNECTION

CONNECTION —

Natural Gas Grills

Natural Gas Grills

GAS LEAK CHECKS

Before operating your grill, check carefully to be certain that all connections are tight
and there are no gas leaks. Never use a match or flame for leak detection. Use soapy
water or testing solution. Brush the solution on to connection points and look closely
for bubbles indicating escaping gas. If leaks are detected, shut off the main gas supply
valve and securely retighten connections, then repeat the leak test.

ƽ CAUTION: The appliance and its individual shut off valve

must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures
in excess of 1/2 psig (3.5 kPa).

ƽ CAUTION: The appliance must be isolated from the gas

supply piping system by closing its individual manual shut
off valve during any pressure testing of the gas supply
piping system at test pressures equal to or less than 1/2 psig
(3.5 kPa).

ƽ WARNING: Never use an open flame when testing for gas

leaks! Use of an open flame may result in serious bodily
injury or death, or in a fire or an explosion causing damage
to property.

TYPE OF GAS

Your natural gas grill is factory built to operate using natural gas only. Never attempt to
operate your grill on gases other than the type specified on the grill rating plates.
Your grill operates at 7" of water column pressure. If replacement of the hose becomes
necessary, factory specified parts are required. See your local dealer.

For safety and design reasons, the conversion of a Ducane

®

grill from operation using

Natural gas to operation using LP gas requires the change out of the entire gas supply
system of the grill. If this becomes necessary, see your dealer for additional information.

WHAT IS NATURAL GAS?

Natural gas, often called methane, is a safe modern fuel. Natural gas is supplied by your
local utility and should be readily available if your house is already heated with gas.

PORTABLE INSTALLATION

Limited portability can be afforded to the grill head when mounted on the portable cart.
All grill heads mounted on this portable cart and cabinet model grills so equipped can be
moved about 10 feet away from the main gas supply. Ducane recommends moving the
grill at least two (2) feet from the gas supply and any combustible surfaces.

After the gas supply has been run and checked for leaks in accordance to the assembly
instructions, you are ready to grill. To connect the hose to the gas supply, pull back
the outer fitting, insert the hose fitting all of the way, and release the outer fitting. This
process will produce a gas joint.

Follow special storage instructions located in the Helpful Hints section of this manual for
proper care of your grill and its gas hose.

NATURAL GAS INSTALLER’S GUIDE

This guide is a recommendation for natural gas installations. It advises the installer
as to the size tubing that is necessary on a natural gas installation depending
on how far the grill is located from the house. All tubing should be anticorrosive
tin-lined copper or an AGA-approved alternate. Operating pressure of the grill is 7"
water column pressure. This should be verified after the installation is complete.
Comparable sized black iron pipe is also acceptable for natural gas lines.

Distance

Pipe Size

1 - 25 feet

3/8"

26 - 50 feet

1/2"

51- 100 feet

2/3 of the run 3/4" down to 1/2"

101 feet or more

3/4"

6

5

3

7

1

2

4

1

Flare Union

2

Swivel Connection

3

Install covers when hose is disconnected

4

Shut Off Valve

5

Coat this pipe nipple with gas resistant pipe dope

6

Socket

7

Male Connection

1

3

F L O W

F L O W

F L O W

2

4

1

Socket

2

Sleeve

3

Plug

4

Push plug until sleeve snaps forward locking plug in socket. (This turns

on gas automatically.)

F L O W

F L O W

F L O W

3

2

1

1

Socket

2

Sleeve

3

Push Sleeve Back

When properly assembled the plug cannot be removed without pushing

the sleeve back. To disconnect, push sleeve back and pull out plug.

(This automatically shuts off gas.)