Installing your hob in complete safety

4 cm mini

26 ,5 /56 /75 cm

49 cm

4 cm mini

4 cm mini

F

itting

A seal exists for preventing
any humidity getting under
the hob.
-Stick the seal under the rim
of the hob and lower the
hob into position on the
worktop.
-This seal is supplied in the
sachet; stick it in place
beneath the hob.

These hobs are delivered with type H 05 VVF power cable (1.5mm²) with 3/5 conductors (including a
green/yellow earth wire), which must be connected to the power supply via a plug that complies with
publication CEI 83 or an all-pole cut-out unit with contacts that open by at least 3mm.
If the cable is damaged,

it must be replaced by an authorised St George Service Agent or similarly

qualified person for avoiding any possible risk of accident.
When the power is switched on, or after a long power failure, a light

code appears on the control panel.

This disappears automatically after

about 30 seconds or as soon as any touch control is touched on the

panel. This is normal, as the display is for use by the after-sales service when required. The user must not
take this into account under any circumstances. If the unit has a 3 phase 400 V2N connection, and is not
working correctly, check that the neutral wire is correctly connected. This precaution should also be taken
for all your other electronic apparatus.

The unit must be installed so that the mains plug is easily
accessible.

C

onnection

78,3

52

48,8

74,5

5,9

dimensions in cm

75

Neutral

Earth

Phase 2

Phase 1

N L1

L2

Separate the 2 phase
wires L1 and L2 before
connecting

Blue

Green/yellow

Black

- 400 V 2N three-phase

fuse : 16 Amp

brown

Neutral

Earth

Phase

N

L

- 220-240 V monophase

fuse : 32 Amp

Green/yellow

Blue

Black

brown