5.

TROUBLESHOOTING

Problem

Cause

The main switch indicator will not

light up

No electricity connected to the machine

• Check the mains supply fuses.

• Check the mains cable and plug.

Poor welding result

Several factors affect the welding quality.

• Check that the earthing clamp is firmly attached, the point of

attachment is clean and that the cable and its connectors are

intact.

• Check that the shielding gas flows out of the torch tip.

• Check that the electric voltage is not irregular or too low/high.

Overheating indicator lit

The device has overheated.

• Ensure that cooling air has unrestricted flow.

• If the machine’s duty cycle has been exceeded, wait for indicator

to turn off.

• Too low or high supply voltage.

If the machine’s malfunction is not eliminated with these measures, contact

KEMPPI service.

6.

TECHNICAL DATA

Minarc 220
Connection voltage

3 ~, 50/60 Hz

400 V –20 %... +15 %

Rated power at max. current

MMA

8.2 kVA (220 A/28.8 V)

TIG

7.2 kVA (220 A/18,8 V)

Supply current,

I

1max

MMA

12 A (220 A/28.8 V)

TIG

8 A (220 A/18.8 V)

Supply current,

I

1eff

MMA

8 A (150 A/26.0 V)

TIG

6 A (160 A/16.4 V)

Connection cable

H07RN-F

4G1.5 (5 m)

Fuse (delayed)

10 A

Load capacity 40 °C

MMA 35 % ED

220 A/28.8 V

100 % ED

150 A/26.0 V

12