2 general view of the machine, 3 distribution network, 4 cable connections – Kemppi Adaptive 180 User Manual
Page 8
EN
2.2
general View OF tHe MaCHine
1. Welding gun
2. Earthing cable
3. Main switch
4. Supply voltage cable
5. Shielding gas hose connector
2.3
distriButiOn netwOrk
All regular electrical devices without special circuits generate harmonic
currents into distribution network. High rates of harmonic current may cause
losses and disturbance to some equipment.
WARNING: This equipment does not comply with IEC 61000-3-12. If it is
connected to a public low voltage system, it is the responsibility of the
installer or user of the equipment to ensure, by consultation with the
distribution network operator if necessary, that the equipment may be
connected.
2.4
CaBle COnneCtiOns
Connection to the mains
The machine is equipped with a 3.3 m long supply voltage cable and plug.
Connect the supply voltage cable to the mains.
NOTE!
The fuse size needed is 16 A delayed.
If you use an extension cord, its cross-sectional area should be at least as
large as the supply voltage cable’s (3 x 2.5 mm²). The maximum length for the
extension cord is 50 m.
6
M
inar
cM
ig 180 / © Kemppi O
y / 1117