beautypg.com

Installation – Kemppi ARC800 User Manual

Page 7

background image

EN

1.3.2 Control panel

P1

P2

P3

P4

P5

P1

Left display (gouging current or name of adjustable parameter)

P2

Indicator lights for the current area

P3

Right display (gouging voltage or value of adjustable parameter)

P4

Setup button

P5

Control knob (gouging current adjustment, factory reset)

2.

installatiOn

2.1

pOsitiOninG OF the maChine

Place the machine on a firm, dry and level surface. Where possible, do not allow dust or other

impurities to enter the machines cooling air flow. Preferably site the machine above floor level;

for example on a suitable carriage unit.
Notes for positioning the machine

• The surface inclination should not exceed 15 degrees.

• Ensure the free circulation of the cooling air. There must be at least 20 cm of free space in

front of and behind the machine for cooling air to circulate.

• Protect the machine against heavy rain and direct sunshine.

Note!

the machine should not be operated in the rain as the protection class of the machine, IP23S,

allows for outside preserving and storage only.

NOTE!

Never aim metallic grinding spray/sparks towards the equipment.

5

KempG

ouge AR

C 800 / © Kemppi O

y / 1117