3.5 Adjusting welding dynamics
The adjustment of MIG welding dynamics influences the properties of the welding arc and the
amount of splatter. The recommended basic setting is ‘0’. The values -> min (-1...-9) provide a
softer arc for diminishing the amount of spatter. The values -> max (1...9) provide a coarser arc,
suitable when increased arc stability is desired and when using 100% CO₂ shielding gas for
welding steel.
3.6 Thermostat
The temperature control of the machine prevents the power source from over-heating.This
means that the machine can not become damaged if loading exceeds the specified load
factor during welding. When the signal lamp indicating overheating is lit, the welding circuit
can not be activated. The lamp will turn off after a pause of about three minutes, and welding
can be started again in the usual way by pressing gun switch.
3.7 Wire feed switch
The wire feed switch will start the wire feed motor without opening the gas valve. The power
source will start up, but without providing welding power.