beautypg.com

Kemppi MR 200 User Manual

Page 9

background image

EN

Weld data (5)


The weld data function is activated by pressing the button. The weld data function returns the

welding current and voltage values to the displays that were in use during the last weld.
Selection of welding process (7)

The welding process – normal MIG/MMA – can be chosen by the welding process selection

button. In MIG welding wire feed speed and welding voltage are adjusted separately.
Electrode welding (MMA) is selected by pressing the button for >1 second.

NOTE!

When electrode welding is selected, the power source, the electrode holder connected to it

and the MIG gun become energised (open circuit voltage).

Selection of MIG operating procedure (8)

Gun trigger logic selection.
Short Press: 2T / 4T selection.
Long Press: Setup functions.
Setup (8)


When the adjustment of SETUP parameters has been confirmed with long press of the SETUP

button (8b), the adjustable parameter is selected via left potentiometer (control knob), and

the name of the parameter is shown on the left display. Parameter value is selected from

right potentiometer (control knob), and the value can be seen on the right display. (See the

information on SETUP functions).
Remote Selection Button (11)

Remote control unit is connected to the device by pressing button 11. The wire feed speed

and welding voltage setting operations are performed via remote control. In this case,

potentiometers 9 and 10 (control knobs) of the panel are disconnected.

7

© Kemppi Oy / 1515

This manual is related to the following products: