Specifications, Optional positioning of thermostat sensing bulb – Desa CCL3018PTA User Manual
Page 29
www.desatech.com
113097-01C
29
4. The mounting clip must be a minimum of 3"
from bottom of fireplace to prevent crimping
of capillary. Once you have decided on a
location, clean the area thoroughly. Remove
the paper backing from the adhesive on back
of mounting clip. Press the clip into the new
location so that the thermostat sensing bulb
will be positioned vertically with the capil-
lary at the bottom (see Figure 44). Slide the
thermostat sensing bulb into the clip.
IMPORTANT:
Do not crimp capillary.
Figure 44 - Positioning the Thermostat
Sensing Bulb in the Vertical Position
with the Capillary at the Bottom
Capillary
Thermostat
Sensing Bulb
Do Not Crimp
Capillary
Adhesive-backed
Mounting Clip
OPTIONAL POSITIONING
OF THERMOSTAT
SENSING BULB
Continued
SPECIFICATIONS
DUAL BURNER BILTMORE SPLIT OAK MODELS
CCL3018PTA
CCL3924PTA
CCL3930PTB
Btu (Variable)
16,000/30,000
20,000/39,000
20,000/39,000
Type Gas
Propane/LP
Propane/LP
Propane/LP
Ignition
Piezo
Piezo
Piezo
Manifold Pressure
8.0" W.C.
8.0" W.C.
8.0" W.C.
Inlet Gas Pressure (in. of water)
Maximum
14"
14"
14"
Minimum*
11"
11"
11"
Shipping Weight
61 lbs.
66 lbs.
70 lbs.
* For the purpose of input adjustment
CCL3018NTA
CCL3924NTA
CCL3930NTB
Btu (Variable)
16,000/30,000
20,000/39,000
20,000/39,000
Type Gas
Natural
Natural
Natural
Ignition
Piezo
Piezo
Piezo
Manifold Pressure
3.5" W.C.
3.5" W.C.
3.5" W.C.
Inlet Gas Pressure (in. of water)
Maximum
10.5"
10.5"
10.5"
Minimum*
5"
5"
5"
Shipping Weight
61 lbs.
66 lbs.
70 lbs.
* For the purpose of input adjustment
SINGLE BURNER SEASONAL OAK MODELS
CRL2718PA
CRL2718NA CRL3124PA
CRL3124NA
Btu (Variable)
16,000/27,500 16,000/27,500 16,000/31,500 16,000/31,500
Type Gas
Propane/LP
Natural
Propane/LP
Natural
Ignition
Piezo
Piezo
Piezo
Piezo
Manifold Pressure
8.0" W.C.
3.5" W.C.
8.0" W.C.
3.5" W.C.
Inlet Gas Pressure (in. of water)
Maximum
14"
10.5"
14"
10.5"
Minimum*
11"
5"
11"
5"
Shipping Weight
49 lbs.
49 lbs.
53 lbs.
53 lbs.