CARE AND MAINTENANCE

HYDROSTAT DRIVE BELT

REPLACEMENT PROCEDURE:

To install hydrostat pump drive belt:

1.

Rotate the spring loaded take-up idler towards
the left hand hydro pump.

2.

Install belt per diagram.

3.

Install double u-joint and tighten flange bolts
(tighten to 14 ft. lbs.).

4.

Install radiator and mounting hardware.

5.

Attach radiator hoses and refill cooling system.