beautypg.com

Filtration information, Care and use – InSinkErator SST-FLTR Tank and Fliter System User Manual

Page 8

background image

FILTRATION INFORMATION

Do not use with water that is microbiologically unsafe or of unknown quality without adequate

disinfection before or after the system.

To reduce the risk associated with property damage due to water leakage:

• Protect filter from freezing. Drain filter when temperatures drop below 40°F (4.4°C).
• Do not install if water pressure exceeds 120 psi (828 kPa). If your water pressure

exceeds 120 psi, you must install a pressure limiting valve. Contact a plumbing

professional if you are uncertain how to check your water pressure.

• Do not install where water hammer conditions may occur. If water hammer

conditions exist you must install a water hammer arrester. Contact a plumbing

professional if you are uncertain how to check for this condition.

• Do not install on hot water supply lines. The maximum operating water temperature of

this filter system is 100°F (38°C).

• The disposable filter cartridge must be replaced every twelve months or at the

specified service cycle.

• Read and follow instructions before installation and use of this system.

The InSinkErator

®

Instant Hot Water Dispenser Filtration System is intended for use in filtering

sediment, chlorine taste and odor from drinking water, and has not been evaluated for other

uses. The system is typically installed (near or beneath a sink) where filtered drinking water is

desired, and must be installed, operated and maintained as specified in the installation and

use instructions.

F-201R Cartridge (included with this system) Chemical & Mechanical Reduction Filter Specifications:

This cartridge provides mechanical and chemical reduction of dirt/rust, taste/odor and chlorine.

Filter Capacity: 500 gallons, depending on local water conditions. Note that while the testing was performed under

standard laboratory conditions, actual performance may vary. Do not use with water that is microbiologically unsafe or
of unknown quality without adequate disinfection before or after the system. For cold water use only. Systems must be

installed and operated in accordance with the Manufacturer’s recommended procedures and guidelines. See warranty
card for warranty. For service and parts, contact your local dealer or InSinkErator

®

directly at 1-800-558-5700.

Application guidelines/Water Supply Parameters for NSF Testing: Service flow of 0.75 gpm, community or

private well water supply, water pressure of 20-120 psi, water temperature of 33˚F–100˚F. Except as noted, all
testing performed at pH = 7.5 ± 0.5, Flow: 0.75 gpm, Pressure: 60 psi, Temp: 20˚±3˚C.

Contact an authorized InSinkErator service agent for repairs or replacement components.

Pressure: 20-120 psi

Temperature: 33

º

F - 100

º

F

Flow Rate: 0.75 gpm

Capacity: 500 gallons

Tested and Certified by NSF International against
NSF/ANSI Standard 42 in model F-201 for the reduction
of claims specified on the Performance Data Sheet.

Electric Shock Hazard: To prevent electrical shock, disconnect power before

servicing unit. Use only a properly grounded and polarized electric outlet.

CARE AND USE

Scalding Hazard: Do not allow

water to boil. May result in

severe burns.

Factory temperature pre-set is 200˚F.

To reset the thermostat to 200°,

turn the indicator two notches to

the right of vertical.

Adjust the thermostat

slowly, turning the dial

clockwise to increase

temperature or counter

clockwise to decrease temperature, then

activate faucet handle for 20 seconds to

bring in fresh water to be heated at the new

setting. Allow 5-7 minutes for water to reach

new temperature.

ADjUSTINg THE THERMOSTAT

Only use mild cleaners to clean the faucet

and plastic components.
Cleaners with acids, abrasives, alkaline or

organic solvents will result in deterioration of

the plastic components and void the warranty.

CLEANINg THE FAUCET AND TANK

Replace filter cartridge when there is an obvious decrease

in water flow to the faucet or if there is an objectionable

taste or odor to the water.

When the inlet and outlet ports have been closed and

the filter’s internal pressure has been relieved, water

(about 2 oz) will discharge from vent line.

If the new filter cartridge cannot be inserted, insert the

old one and turn until it stops, remove it and then retry

the new cartridge.

Carbon filters should be replaced within 12 months.

FILTER gUIDE AND REPLACEMENT

Filter replacement instructions:

Replace with an InSinkErator

®

filter.

Place pan or dish towel under the filter to

catch water drainage during change.

Slowly turn the cartridge counter-clockwise

completely until it stops (1/4 turn).

Pull cartridge straight down and discard.
Insert new cartridge into filter head.
Top surface of cartridge will become flush

with the bottom of the filter head when

fully engaged.

Turn the cartridge clockwise until it stops

(1/4 turn).

Align the in/out arrow on the head and

bracket assembly to the in/out arrow on

the cartridge.
Open faucet to expel trapped air.

Run water for 3 minutes before usage.

Regularly inspect the unit for any signs of

leakage. If there are signs of water damage,

immediately remove the unit from service.
To avoid water damage from leakage,

replace all cut, loose or split tubing.
A drain pan, plumbed to an appropriate

drain or outfitted with a leak detector,

should be used in those applications where

any leakage could cause

property damage.

PROPERTY DAMAgE

Anytime the instant hot water dispenser is not used for

extended periods of time, unplug and drain unit. If it is below

freezing you will need to unplug the unit and drain it.

Disconnect power from unit (unplug unit).
Push hot water dispenser faucet lever and

allow water to flow until it is cool.
Shut the cold water supply off at the valve.
Disconnect tubes from the tank.
Unhook tank from wall.
Hold tank upside down and drain the water

into the sink.
Towel dry any water drippings from tank area.
Reinstall tank to wall and reconnect tubes.
Remove and discard filter cartridge,

if applicable.
To put back into working order, install new

filter cartridge (if applicable) and turn on cold

water supply at valve. Depress the hot water

dispenser faucet lever and hold until water

flows from the spout. Reconnect the

electrical cord. (Refer to Page 11, Step 6B)

SEASONAL STORAgE/DRAINAgE

approx. 200°

Regularly check for signs of corrosion

by examining the appearance of the

dispensed water.
If there is any discoloration or rusty appearance,

unplug and drain unit as described in the

Seasonal Storage/Drainage section on this

page of the manual.
If the water discoloration remains after

draining and refilling unit, discontinue use

and contact an authorized InSinkErator

service agent.

PERSONAL INjURY

14

15