INSTALLATION INSTRUCTIONS
Placement
Carefully uncrate machine. Take caution not to
damage components which may be mounted on
the top or sides of the machine. Set unit in place
and adjust the feet to level the machine.
Fasten the tables to the load and unload side of the
machine. Most installations require fastening the
turn-down lip of the dish table to the side of the
machine with flathead counter-sunk screws. The
table design should provide horizontal clearance of
30” for servicing underneath the table.
Electrical Connections
Connect electrical lines sized for the correct volt-
age, current and phase of the machine. These
should agree with the machine requirements
indicated on the nameplate and labels on the
control panel.
Model
208VAC/3È
230VAC/3È
380VAC/3È
460VAC/3È
220VAC/IÈ
Admiral 44-4
Steam or Electric
15A
10A
10A
6A
20A
Admiral 44-4
Steam or Electric
Power Loader
15A
15A
10A
6A
25A
Admiral 44-4
Steam or Electric
Power Unloader
15A
15A
10A
10A
25A
Admiral 44-4
Steam or Electric
Power Loader
Power Unloader
20A
15A
10A
10A
25A
Admiral 44-4
Gas Heat
15A
15A
10A
6A
20A
Admiral 44-4
Gas Heat
Power Loader
Power Unloader
15A
15A
10A
10A
25A
Admiral 44-4
Admiral 66-4
Electric Heat
Single-Point Electric
60A
50A
30A
25A
n/a
FUSE SIZING CHART
Admiral 44-4
Electric Heat
Single-Point Electric
Power Unloader
60A
50A
30A
25A
n/a
On machines not provided with a single-point con-
nection (optional) there is an electrical connection
required for the:
1. Pumps and control circuit, 2.
Wash tank heater(s) and,
3. Rinse tank heaters
(if provided).
If an electric booster is provided, connect power
directly to the booster.
Fusing must be in accordance with the Fuse Sizing
Chart below.
PART 2 INSTALLATION INSTRUCTIONS
CAUTION:
Connections must be made to a circuit breaker
or fused disconnect as provided by the
end-user and required by local codes.
A laminated wiring diagram is inside the control panel.