Jp5: clear cmos contents, Jp1, jp2, jp3: rs232/422/485 (com2) selection – IBASE MI950 User Manual
Page 14
INSTALLATIONS
JP4: ME (Management Engine) – Disabled / pin closed
The factory default setting of the 2-pin JP4 jumper is closed. This means
the management engine function is disabled.
JP5: Clear CMOS Contents
Use JP8, a 3-pin header, to clear the CMOS contents.
Note that the ATX-power connector should be disconnected from the
motherboard before clearing CMOS.
JP5
Setting
Function
Pin 1-2
Short/Closed
Normal
Pin 2-3
Short/Closed
Clear CMOS
JP1, JP2, JP3: RS232/422/485 (COM2) Selection
COM2 is selectable for RS232, RS-422 and RS-485.
COM2
Function
RS-232
RS-422
RS-485
Jumper
Setting
(pin closed)
JP1:
1-2
JP2:
3-5 & 4-6
JP3:
3-5 & 4-6
JP1:
3-4
JP2:
1-3 & 2-4
JP3:
1-3 & 2-4
JP1:
5-6
JP2:
1-3 & 2-4
JP3:
1-3 & 2-4
10
MI950 User’s Manual