SPECIFICATIONS
System Requirements
Gas Requirements:
Plasma Gas Types ......................................Oxygen (O
2
), Air
Shield Gas Type ..........................................Oxygen (O
2
) and Nitrogen (N
2
) mixture,
Methane (CH4) and Air mixture, Methane
Gas Quality..................................................Oxygen and Nitrogen – 99.995 pure
(liquid gas recommended)
Air – Clean, dry and oil-free
Methane – 93% pure (commercial grade)
All Gas and Air Inlet Pressure .....................120 psi (8.3 bar)
Oxygen and Air Flow rate ............................77.7 scfh (2200 l/hr) at full-scale
Nitrogen Flow rate .......................................83.1 scfh (2353 l/hr) at full-scale
Methane Flow rate.......................................108 scfh (3058 l/hr) at full-scale
Torch Coolant Requirements (torch coolant requirements are provided by power supply.)
Coolant Tank Capacity.................................2.9 gallons (11 liters)
Coolant ........................................................Ethylene Glycol/Deionized Water
Flow Rate ....................................................1.4 gpm (5.3 l/m)
Pressure ......................................................150 psi (10.2 bar)
HD1070 Power Supply
Dimensions and Weight
Width ...........................................................24-1/4" (616 mm)
Height ..........................................................36" (914 mm)
Depth ...........................................................38-1/4" (972 mm)
Weight .........................................................545 pounds (247 kg)