beautypg.com

Service manual, Pecifications – Hypertherm Powermax900 Service Manual User Manual

Page 27

background image

2-6

S

PECIFICATIONS

Service Manual

4.5" (114 mm)

3.5" (89 mm)

Figure 2-5 Power Cord Preparation - Non-CE

L1

L2

L3

Ground

#10

Figure 2-6 Power Cord Preparation - CE

4.75" (120 mm)

3.75" (95 mm)

L1

L3

#10

L2

0.5" (13 mm)

Ground

All wires 1 turn
through 109068 toroid.

Power Requirements

Line Voltage Disconnect Box

Use a line disconnect box for each power supply. This disconnect box allows the operator to turn the
power supply off quickly in an emergency situation. The switch should be located on a wall near the
power supply, and should be easily accessible to the operator. The interrupt level of the switch must be
equal to or exceed the continuous rating of the fuses. Use slow-blow fuses according to the power
requirements listed below.

Input

Input Current

Recommended

Voltage

Phase

@ 6.6 kw Output

Slow-Blow Fuse Size

200 VAC

1

57 amps

70 amp

208 VAC

1

55 amps

70 amp

230 VAC

1

50 amps

70 amp

240 VAC

1

47 amps

60 amp

400 VAC

1

33 amps

40 amp

480 VAC

1

28 amps

35 amp

200 VAC

3

33 amps

40 amp

208 VAC

3

32 amps

40 amp

230 VAC

3

29 amps

35 amp

230 VAC (CE)

3

31 amps

40 amp

240 VAC

3

28 amps

35 amp

400 VAC

3

18 amps

25 amp

400 VAC (CE)

3

18 amps

25 amp

480 VAC

3

15 amps

20 amp

600 VAC

3

12 amps

20 amp