beautypg.com

Powermax190 – Hypertherm Powermax190c Service Manual User Manual

Page 31

background image

3-6

powermax190

c

Service Manual

MAINTENANCE

WARNING

ELECTRIC SHOCK CAN KILL

SHOCK HAZARD:

Always turn off power and unplug cord from wall and wait 5 minutes before

removing any cover of the power supply. If power supply is directly connected to a line disconnect box,
place line disconnect switch to OFF position. In the U.S., use a “lock-out / tag-out” procedure until the
service or maintenance work is complete. In other countries, follow appropriate national or local safety
procedures.

If power is required for servicing, be aware that dangerous voltages exist within the power supply
which could cause serious injury or death. If questions or problems arise during servicing, call the
Hypertherm Technical Services department listed in the front of this manual.

WARNING

ELECTRIC SHOCK CAN KILL

SHOCK HAZARD:

Do not attempt repairs on the power board. Do not in any way cut away or remove

the protective conformal coating from the board. To do so will risk a short between the AC input circuit
to the output circuit and may cause serious injury or death.

The power supply and PC boards are subjected to dielectric and insulation resistance tests per
applicable CSA and IEC standards for the safety of the operator and service technicians.

Removal of the protective conformal coatings and other unauthorized repairs to the PC boards will void
the warranty.

If questions or problems arise during servicing, call the Hypertherm Technical Services department
listed in the front of this manual.

1. Set the Powermax190c power switch to O (off) and unplug the power cord.

2. Remove the cover of the power supply by removing the securing screws.

3. Visually inspect the inside of the power supply, especially on the side with power board PC1 (see Section 4).

Look for broken or loose wiring connections, burn and char marks, damaged components, etc. Repair or replace
as necessary.

Visual Inspection – Internal