OPERATION

HT4400 with Titan Gas Panel

Instruction Manual

3-3

0

Gas Panel Controls and Indicators

PG1

Indicates the plasma gas pressure. Settings for the plasma gas pressures are specified in the
Cut Charts in manual 803580, Operation section.

S1

Selects the use of either nitrogen or oxygen as the plasma cutting gas.

Status

Displays a 2 character code to report the condition of the HT4400 system. See Status

Display

Display Messages on the Gas Console in operation section of manual 803580. See also Error
Code Troubleshooting
in Section 5.

PG2

Indicates the shield gas pressure. Settings for the shield gas pressures are specified in the
Cut Charts (manual 803580).

MV1

Adjusts the plasma gas cutflow pressure. MV1 and cutflow plasma pressures are specified in
the Cut Charts.

MV2

Adjusts one of the plasma gas preflow pressures. MV2 and preflow plasma pressures are
specified in the Cut Charts. .

MV3

Adjusts one of the shield gas cutflow pressures. MV3 and cutflow shield pressures are
specified in the Cut Charts.

MV4

Adjusts one of the shield gas preflow pressures. MV4 and preflow shield pressures are
specified in the Cut Charts. .

MV5

Adjusts one of the plasma gas preflow pressures. MV5 and preflow plasma pressures are
specified in the Cut Charts. .

MV6

Adjusts one of the shield gas cutflow pressures. MV6 and cutflow shield pressures are
specified in the Cut Charts.

MV7

Adjusts one of the shield gas preflow pressures. MV7 and preflow shield pressures are
specified in the Cut Charts.

Gas Select 1 Selects the plasma cutting gas (Gas 1). When the shield gas is a mixture of 2 gases, this

setting represents the plasma portion of the mixture.

Gas Select 2 Selects the shield gas (Gas 2). When the shield gas is a mixture of 2 gases, this setting

represents the non-plasma portion of the mixture.

Valve Select Chooses the active valve to adjust. Also selects Leak Test 1, Leak Test 2, Test Preflow,

S2

and Test Cutflow.

Leak Test 1

See Gas Console Valve Select Detail in Section 5 (manual 803580).

Leak Test 2

See Gas Console Valve Select Detail in Section 5.

Test Preflow

See Gas Console Valve Select Detail in Section 5.

Test Cutflow

See Gas Console Valve Select Detail in Section 5.

Run

In this mode, all valves are OFF initially. The valve select switch must be positioned to
RUN before sending the START command to the plasma system
.