Lhf power supply, Lhf machine torch – Hypertherm HT2000LHF Product Configuration User Manual
Page 8
SPECIFICATIONS
HySpeed HT2000LHF
Product Configuration Manual
1-3
2
LHF Power Supply
Maximum OCV (U
0
) .............................................280 VDC
Output Current (I
2
)................................................40 – 200 amps
Output Voltage (U
2
) .............................................150 VDC
Duty Cycle Rating (X) ..........................................100% up to 30 kW. Beyond 30 kW, Duty Cycle (X) =
(30 kW/Actual Power)
2
Eg: If Actual Power = 32 kW, then
Duty Cycle (X)= (30 kW/32 kW)
2
= 88%
Ambient Temperatures/Duty Cycle ......................Power supplies will operate between +14° and 104° F
(-10° and +40° C). Power supplies operated in an ambient
temperature above 86° F (30° C) may show some
decrease in duty cycle.
Power Factor (cos
ϕ
).............................................0.86
Input Power (Input Voltage (U
1
) x Input Current ( I
1
)):
073227 with THC; 073228 without THC...............200 VAC, 3PH, 50 Hz, 108 amps
073229 with THC; 073230 without THC...............208 VAC, 3PH, 60 Hz, 104 amps
073231 with THC; 073232 without THC...............240 VAC, 3PH, 60 Hz, 90 amps
073235 with THC; 073236 without THC...............400 VAC, CE, 3PH, 50 Hz, 56 amps
073262 with THC; 073263 without THC...............440 VAC, 3PH, 50-60 Hz, 49 amps
073233 with THC; 073234 without THC...............480 VAC, 3PH, 60 Hz, 45 amps
073237 with THC; 073238 without THC...............600 VAC, 3PH, 60 Hz, 36 amps
Dimensions and Weight:
Width ....................................................................28-1/4" (710 mm)
Height ...................................................................35-1/2" (900 mm); 40-3/4" (1035 mm) on CE units
Depth....................................................................41-1/4" (1045 mm)
Weight ..................................................................780 lbs (351 kg); 800 lbs (363 kg) on CE units
Cooling .................................................................Forced Air (Class F)
Coolant Tank Capacity .........................................2.9 gallons (11 liters)
Maximum cutting thickness ..................................2" (50 mm)
Maximum current at 100% duty cycle ..................200 amps
Plasma and Shield Gas Flow ...............................Refer to the Cut Charts in the Operation section of
instruction manual 803020 for specific gas requirements.
Water coolant flow rate ........................................0.8 gpm (3.0 l/min)
Weight ..................................................................3 lbs (1.36 kg)
2" (50 mm) or
1.75" (44 mm)
2"
(51 mm)
4.3"
(109 mm)
6"
(152 mm)
15.4"
(391 mm)
23.25"
(590 mm)
Figure 1-1
LHF Machine Torch
(standard torch shown.)
LHF Machine Torch