SPEEDOMETER SETUP
Main Menu

Sub Menu

Description

SPd

dIAG

Read diagnostic codes from engine or security modules.

AdJvSt

select adjust calibrate speed

vnIt

select speed unit (MPH or km/h, default MPH)

S SEt

miles to service setting (default off)

PErF

enable/disable performance readings (default on)

FvEL

select fuel sender type (default off)

RANGE

setup miles to empty function

-odoMK

one-time odometer preset (only shown while odometer has less than 100 miles)

Press and hold the switch while turning the key on. Release the switch. The speedometer will show “

-1-

”. Press

and release the switch so that “

SPd

” is displayed. Press and hold the switch for about 3 seconds until “

-

” is displayed.

Release the switch. The MPH display will show “

SEt

” and the odometer display will show “

dIAG

”. Press and release the

switch to move through the different speedometer setup menus; press and hold the switch to select a menu option.


dIAG

dIAG

dIAG

dIAG

Diagnostics mode for checking/clearing trouble codes

Press and release the switch until “

dIAG

” is displayed, then press and hold the switch until “

-

” is displayed.

Release the switch. The display will show “

ENGINE

”, “

SECvRE

”, “

ABS

”, or “

DoNE

”.

Press and release the switch to change the selection, press and hold the switch until “

-

” is displayed to begin reading the stored

codes for the particular system.

Release the switch. The display will show the current codes, “

none

”, or “

no rsp

”. Press and release the switch to move to the

next stored code. After all codes are displayed the module part number will be scrolled across the screen. To clear codes, press
and hold the switch when “end” is displayed. Consult a service manual for trouble code descriptions.


Ad

Ad

Ad

AdJ

JJ

Ju

uu

uS

SS

St

tt

t

Speed Calibration

The speedometer is calibrated by the engine computer, but the speedometer reading can be adjusted through the

gauge. The adjustment is set a value from 0.75(75%) – 1.25(125%) with 1.00 being no change.

Press and release the switch until “

AdJvSt

” is displayed, then press and hold the switch until “

-

” is displayed.

Release the switch. The display will show “

SLoWJ

” or “

FASTER

”. Slow will make the speedometer read lower, faster will make the

speedometer read higher. Press and release the switch to change the selection, press and hold the switch until “ - ” is displayed
to continue on.

Release the switch. The display will show “

CL 1

.

00

” or whatever the current calibration ratio is.

Press and release the switch to change the adjustment ratio. Press and hold the switch until “

-

” is displayed to save the

currently displayed ratio.


v

vv

vn

nn

nI

II

It

tt

t

MPH/km/h Selection

Press and release the switch until “

vnIt

” is displayed, then press and hold the switch until “

-

” is displayed.

Release the switch. The display will switch to “

vnIt

” and light up the current speed unit (MPH or km/h).

Press and release the switch until the desired setting is displayed.

Press and hold the switch until “

-

” is displayed to the setting.


S S

S S

S S

S Se

ee

et

tt

t

Miles to Next Service setup

The service mileage is a countdown mile meter. The service mile display can be disabled or can be set to count down from

500 – 7500 miles. If the service mile is enabled and it gets to 0 miles, it will display “

S -DUE

” each time the key is turned on. If the

push button switch is pressed and held while “

S ----

” is displayed, the service miles will be reset.

Press and release the switch until “

S SEt

” is displayed, then press and hold the switch until “

-

” is displayed.

Release the switch. The current setting will be displayed. (“

oFF

” or a mileage from 500 – 7500 in increments of 500.)

Press and release the switch until the desired setting is displayed.

Press and hold the switch until “

-

” is displayed to save the setting.