Installation guide, Requirements, Fiber optic link cabling – Guntermann & Drunck USB 3.0 Spectra 3022 User Manual
Page 7

Installation Guide
Example Application
Requirements
To complete installation of the Spectra 3022, you will also require the following items that are not included
with the product:
• USB 3.0 compatible computer (host computer) with a USB 3.0 compliant operating system
• USB 3.0 compatible device
• 2-strand 50/125μm multimode (MMF) fiber optic cable with Duplex LC connectors
note
Up to 15m with Microsoft Kinect; 50m with USB 3.0 storage type devices; 100m or more is achievable when using USB 3.0
bulk traff ic cameras..
Fiber Optic Link Cabling
The LEX and REX are interconnected by fiber optic cabling. This cabling must be:
• 50/125μm multimode f iber (MMF)
• Terminated with Duplex LC connectors
The following maximum distances are achievable depending upon the application and cabling standard:
note
For assistance sourcing appropriate f iber optic cabling, contact
If premise cabling will be used for the installation, then the distances provided above must be met when
measuring from LEX to REX, inclusive of the premise cabling and the patch cables. All cables must meet the
ratings specified. Patch cables must be terminated with Duplex LC connectors.
6
LEX
USB 3.0 Cameras
REX
Assembly Line
Computer & Monitor
USB 3.0 up to 100m
over multimode f iber
Multimode
Fiber Class
Cameras
Storage
Microsoft
Kinect
OM2
50m
50m
15m
OM3
100m
50m
15m
Up to 15m with Microsoft Kinect; 50m with USB 3.0 storage type devices; 100m or more is achievable
when using USB 3.0 bulk traff ic cameras.