beautypg.com

Pecifications, Heating specifications dimensions, Electrical specifications – Dansons Group GLOW BOY IGB User Manual

Page 8: Epa compliance

background image

8

S

S

PECIFICATIONS

PECIFICATIONS

HEATING SPECIFICATIONS

DIMENSIONS









Product subject to
Change without notice.

ELECTRICAL SPECIFICATIONS

Electrical Rating

= 115 Volts 60 HZ 2.0 Amps

Watts (operational)

= 175 (approximately)

Watts (optional igniter)

= 475 (approximately)

A voltage surge protector or ground fault outlet is required for this unit. The warranty on the circuit
board will be voided if surge protection is not installed before operating this unit.

If power outages or disturbances are a concern, you may wish to purchase a gas powered generator,
solar or battery back-up system. Ensure that it is a “Positive” sign wave and a minimum 1000 watts
continual.

EPA COMPLIANCE

This heater is exempt from EPA Phase II requirements, but has been tested for emissions using EPA test
methods by Warnock Hersey , US. Pellet appliances that are designed with the combustion air supply
exceeding 35:1 (by ratio) are exempt from EPA regulations.

Approx. Heating capacity (sq. feet) *

800 – 2,000

Approx. Fuel burn rate per hour **

1.5 – 5 lbs

Hopper Capacity - Bay View Freestanding

60 lbs

Approx. Burn time at lowest setting

48 hrs

Hopper Capacity – Bay View Insert / Built-in

40—60 lbs.

Approx. Burn time at lowest setting

27-48

Hopper Capacity - Freestanding Step Top

90 lbs

Approx. Burn time at lowest setting

65 hrs

Hopper Capacity— Classic Insert / Built-in

40 lbs.

Approx. Burn time at lowest setting

27 hrs

Glow Boy Pellet & Biomass www.glowboystoves.com 8

24”

32 ½”

24”

18 3/4”

+

+

Shroud 1”

+

+

24”

6 1/2”

7 3/4”

8 1/4”

3 ½”

Exhaust

Air Inlet

8 1/4”

Air Inlet

12 3/4”

6 1/2”

Exhaust

24 3/4”

24”

24 3/4”

12 1/4”

10 3/4”

+

+

24”

8 1/4”

Air Inlet

17 1/4”

12 3/4”

6 1/2”

Exhaust

24 3/4”

30”

24”

+

Shroud 1”

8 1/4”

Air Inlet

17”

12 3/4”

Exhaust

26”

12 1/4”

10 3/4”

+

25”

Air Inlet

7”

Exhaust

+

+

Exhaust

26”

+

24”

6 ½”

Exhaust

+

Air Inlet

8 1/4”

7 3/4”

3 ½”

24”

Bay View Freestanding

Bay View Insert / Built-In

Step Top Freestanding

Classic Insert / Built-In

19”
-
23”

Adjustable
Hopper

¹ Heating capacity will vary depending on floor plan layout of your home, degree of insulation, and

the outside temperature. Fuel size, quality, density and moisture level will also have an effect.

¹¹ Pellet size may affect the actual rate of fuel feed and burn times. Fuel feed rates may vary by as

much as 20%. Use PFI listed fuel for best results, pelletheat.org for further information.

This manual is related to the following products: