24
Charging errors
Ready indicator lit, error indicator flashing, SOC indicator 1/2/3/4 flashing:
Cause:
Timeout in the corresponding charging phase or battery capacity too high
Remedy:
Select correct characteristic type according to the enclosed characteris-
tic data sheet and charge again
Cause:
Battery faulty (cell short circuit, heavy sulphation)
Remedy:
Check battery and replace if necessary
Cause:
Optional external temperature sensor has tripped due to over- or under-
temperature
Remedy:
Allow battery to cool, or charge battery in a more suitable area