Technical data – Fronius Acctiva Seller User Manual
Page 52

50
Technical data
Electrical data in-
put 230 V
Standards 230V
Electrical data in-
put 120 V
Standards 120V
Mains voltage
~ 230 V AC ±15%
Mains frequency
50/60 Hz
Mains current
max. 2.9 A eff.
Mains fuse
max. 16 A
Efficiency
max. 95%
Effective power
max. 420 W
No-load power consumption
max. 1.7 W
Protection class (with ground conductor)
I
Maximum permitted mains impedance at the interface
(PCC) to the public grid
none
Mark of conformity
CE
EMC device class
A
IEC 60068-2-6
Sinusoidal vibration (sine 10-55 Hz; 20 cycles / axis; acceleration 5 g)
IEC 60068-2-29
Repetitive shock (25 g / 6 ms / 1000 shocks)
EN 60335-1
EN 60335-2-29
EN 61000-3-2
EN 61000-6-2
(EN 61000-4-2, EN 61000-4-3, EN 61000-4-4)
(EN 61000-4-5, EN 61000-4-6, EN 61000-4-11)
EN 61000-6-4
(Class A)
Mains voltage
~ 120 V AC ±15%
Mains frequency
50/60 Hz
Mains current
max. 7.3 A eff.
Mains fuse
max. 20 A
Efficiency
max. 93%
Effective power
max. 420 W
No-load power consumption
max. 6.9 W
Protection class (with ground conductor)
I
Maximum permitted mains impedance at the interface
(PCC) to the public grid
none
Mark of conformity
cTÜVus
EMC device class
A
UL1236
C22.2 No 107.1-01
FCC CFR 47 Part 15
(Class A)