beautypg.com

Owner’s manual, Operating heater, Inspecting burner – Desa CGN10R User Manual

Page 11: Manual lighting procedure, Continued

background image

11

103549

OWNER’S MANUAL

Control

Knobs

Burners

LOW

OFF

PILOT

HIGH

OFF

PILOT

OFF

Figure 17 - Burner Patterns

OPERATING
HEATER

Continued

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.

Turn control knob clockwise
to the OFF position.

Shutting Off Burner Only
(pilot stays lit)

1.

Turn control knob clockwise to the
PILOT position.

MANUAL LIGHTING

PROCEDURE

1.

Remove front panel (see Figure 10,
page 7).

2.

Follow steps 1 through 5 under
Lighting Instructions
, page 10.

3.

With control knob pressed in, strike
match. Hold match to pilot until pilot
lights.

4.

Keep control knob pressed in for 10
seconds after pilot is lit. After 10
seconds, release control knob.

5.

Replace front panel.

GRH/OV 009

GOOD PILOT

GRH/OV 008

BAD PILOT/LP

Figure 18 - Correct Pilot Flame Pattern

If pilot flame pattern is incorrect, as
shown in Figure 19

• turn heater off (see To Turn Off Gas

to Appliance).

• see Troubleshooting, pages 12

through 14.

Thermocouple

Thermocouple

INSPECTING
BURNER

Figure 19 - Incorrect Pilot Flame Pattern

Pilot Burner

Pilot Burner

Check pilot flame pattern and burner flame
pattern often.

PILOT FLAME PATTERN

Figure 18 shows a correct pilot flame pat-
tern. Figure 19 shows an incorrect pilot
flame pattern. The incorrect pilot flame is
not touching the thermocouple. This will
cause the thermocouple to cool. When the
thermocouple cools, the heater will shut
down.

Figure 20 - Correct Burner Flame Pattern

Figure 21 - Incorrect Burner Flame Pat-
tern

If burner flame pattern is incorrect, as shown

in Figure 21
• turn heater off (see To Turn Off Gas

to Appliance).

• see Troubleshooting, pages 12

through 14.

BURNER FLAME PATTERN

Figure 20 shows a correct burner flame
pattern. Figure 21 shows an incorrect burner
flame pattern.

This manual is related to the following products: